OVERVIEW
280 KW JOHN DEERE Diesel Generator 350 KVA, Three phase, Enclosed type, EPA compliant, J280UC3-IV, Brand New, 2 Years Warranty
- JOHN DEERE 6090HF485, Turbocharged Heavy duty diesel engine, 4 stroke, 1800RPM, Electronic governor, U.S. EPA / CARB TIER 3
- LEROY SOMER LSA462L9, 12 Leads brushless alternator. IP23 drip-proof protection, Insulation class H. Electronic Automatic voltage regulation
- SCHNEIDER, Main line circuit breaker, 3 pole, set mounted, wired and maximum output rated for complete generator protection
- NEXYS, Digital auto-start/stop control panel. All genset parameter, alarms and control functions. CE listed
- TELYS2, ADVANCED / 06x MULTILINGUAL, Digital auto-start/stop control panel with built-in Remote monitoring/control capability. All genset parameter, alarms and control functions. RS232 and RS485 (OPTIONAL)
- DAY TANK, Incorporated metallic fuel tank with electronic level sensing, single wall. Daily autonomy: 390L (103Gal) (8hours runtime autonomy @ 75% load)
EQUIPPED WITH THE FOLLOWING ACCESSORIES AND HIGH PERFORMANCE UPGRADES AT NO EXTRA CHARGE (A US$3,000 VALUE):
- CN08 ENCLOSURE CUSTOM COLOR UPGRADE: RAL9003 Signal White
- EN16 BATTERY DISCONNECT SWITCH KIT, Quick battery disconnect switch, installation included
- AL11 LEROY SOMER AREP, (P.M.G. grade) Alternator’s Auxiliary excitation system for enhanced 300% short circuit reactance and motor starting capabilities 300% (3 IN): 10sec (+R438 Automatic Voltage Regulator upgrade)
- R438 LEROY SOMER Automatic Voltage Regulator upgrade featuring Excitation ceiling setting and Underspeed protection by U/f and LAM function. +/-0.5% voltage regulation
- AD42 Original Engine workshop manual (CD edition)
- ML62 Multilingual English/Spanish User guide, Commissioning and Maintenance manual. Wiring diagrams included (CD edition)
- CEL03 COMPLIANCE WITH CSA MARKING, compliance with CSA NRTL/C marking version II
- CM302 CHARGER KIT, 12V Automatic Battery charger kit. Floater/Equalizer type with overload protection, installation included
- CM302 HEATER KIT, Hotstart Complete Automatic Engine Jackets Coolant preheater with Thermostat Kit, installation included
BRAND NEW AND FULLY PACKAGED DIESEL GENERATOR SET INCLUDES STANDARD:
- IP56 rated Weather proof / Super Silent enclosure. 12 gauge electro zinc coated steel for maximum corrosion resistance
- AUTO start/stop control feature included for remote start via 2-Wire dry contact
- U.S. EPA / CARB TIER 3 compliant engine as per current U.S. Environmental Protection Agency regulations
- Engine Governor and Regulation: Electronic Isochronous for extremely accurate +/-0.5% speed regulation
- 12 lead reconnectable Alternator, brushless, single bearing, IP23 drip proof protection, Insulation class H/H, AVR R250, +/- 0.5% regulation
- Radiator rated for T°of 50°C [122°F] max with mechanical fan
- Microprocessor based control panel
- 12V charging alternator and 12V electrical starter motor
- 12V charged DC starting battery with electrolyte and cables
- 29dB(A) Critical class silencer installed inside the enclosure
- Dry type Air filter, Fuel filter and Oil filter spin-on elements installed
- Mechanically welded chassis with anti-vibration isolators
- Each unit prototype and individually factory load bank tested prior to shipping in ISO9001:2008 Quality Controlled facilities
- User guide, commissioning and maintenance manual. Wiring diagrams included. (English, Spanish or French)
- The generator accepts 100% rated load in one step as per NFPA110 and meets ISO8528-5 class G-3 for transient response
- Many options available: Aluminum enclosures, UL142 listed fuel tanks, UL1008 automatic transfer switches, Remote annunciators and More
- Compliant with ISO3046, ISO8528, BS4999, BS5514, BS5000PT99, AS1359, IEC34, UTE5100, VDE0530?_?_??and?_?_??ISO9001:2008
IP56 RATED WEATHER PROOF / SUPER SILENT ENCLOSURE FEATURES:
- 12 gauge electro-zinc coated steel for maximum corrosion resistance (Phosphatizing degreasing, Non-chromic passivation, Osmosis purified rinsing and High durability polyester resin thermosetting powder paint)
- 29dB(A) Internal-mounted critical silencer and flexible exhaust connector offering maximum component life and operator safety
- Fade-, scratch-, and corrosion-resistant. Automotive-grade textured finish resulting in advanced corrosion and abrasion protection as well as enhanced edge coverage and color retention
- Up to 51mm (2in) Acoustic insulation with hydrocarbon sealing film that meets UL 94 HF1 / FMVSS 302 flammability classification and repels moisture absorption
- Interchangeable modular panel construction. Allows complete serviceability or replacement without compromising enclosure design
- Service access. Multi-personnel doors for easy access to generator set control and servicing of the fuel fill, fuel gauge, oil fill, and battery
- Cooling air discharge. Weather protective design featuring a vertical air discharge outlet grille. Redirects cooling air up and above enclosure to reduce ambient noise
- Cooling/combustion air intake with a horizontal air inlet. Sized for maximum cooling airflow
- Heavy duty Polyamide plastic hinges, Dichromate galvanized bolting and Stainless steel rivets for lifetime longevity
- 100% modular design, complete enclosure can be removed or installed in under 30 minutes, no disassembly required
- Meets and exceeds NFX41002 Salt spray test, NFT30049 UV Performance test, NFT30038 Paint adhesion test and 2000/14EC Low sound directives
GENERATOR POWER RATINGS, VOLTAGES, DIMENSIONS AND WEIGHT:
- STANDARD POWER RATINGS: 280KW (350KVA) STANDBY, 255KW (318KVA) PRIME, 60HZ, 1800RPM, 0.8PF, 3PHASE
- STANDARD VOLTAGES AVAILABLE: 208/120V, 220/110V, 220/127V, 230/115V, 240/120V, 240/139V, 416/240V, 440/254V, 460/265V, 480/277V
- DIMENSIONS ENCLOSED SUPER SILENT TYPE: 4004mm [158in] x 1380mm [54in] x 2145mm [84in], 3290kg [8157lbs] Net
FAQs:
How much fuel does a 300 kVA generator use?
At full load, a 350 kVA generator uses approximately 21.5 gallons (97.7 L) of fuel per hour of use. This means that a 350 kVA generator would use about 172 gallons (782 L) of fuel when run at full load for a typical 8 hour work day. However, the amount of fuel your generator consumes can vary based on many different factors.