OVERVIEW
400 KW MOBILE GENERATOR, John Deere EPA/CARB TIER 4 FINAL
GPR-J400-60T4F-2SA
BRAND NEW, 12GA MARINE-GRADE ALUMINUM SUPER SILENT ENCLOSURE
100% DESIGNED, ENGINEERED, ASSEMBLED AND TESTED IN USA
Available in both trailer and non-trailer versions based upon application requirements and customer needs
MOBILE 500 kVA GENERATOR POWER RATINGS:
>3PHASE 480/277V: 400KW (500KVA) 601A STANDBY, 380KW (475KVA) 571A PRIME, 0.8PF, 60HZ
>3PHASE 208/120V: 400KW (500KVA) 1388A STANDBY, 380KW (475KVA) 1319A PRIME, 0.8PF, 60HZ
>1PHASE 240/120V: 214KW (214KVA) 892A STANDBY, 201KW (201KVA) 838A PRIME, 1.0 PF, 60HZ
POWERED BY PREMIUM HEAVY DUTY INDUSTRIAL COMPONENTS FOR MAXIMUM DURABILITY, EXCELLENT RELIABILITY AND WORLDWIDE SUPPORT:
>DIESEL ENGINE: JOHN DEERE 6135HFG06-1634, Turbocharged & Aftercooled (air-to-air), heavy duty diesel engine, 1800rpm, Liquid cooled, Electronic governor, U.S. EPA / CARB TIER 4 FINAL compliant
>EMISSIONS COMPLIANCE: U.S. EPA / CARB TIER 4 FINAL as per current U.S. Environmental Protection Agency regulations
>AC ALTERNATOR: LEROY SOMER TAL-047-A, 12 Leads brushless alternator. IP23 drip-proof protection, Insulation class H. Electronic Automatic voltage regulation
>ALTERNATOR EXCITATION: LEROY SOMER AREP, PMG-grade auxiliary excitation and AVR upgrade for 270% (270IN:5s) short-circuit reactance capability
>ADVANCED DIGITAL CONTROLLER: DEEPSEA DSE7320 MKII digital auto-start/stop control panel. All genset parameter, alarms and control functions. RS232 and RS485. UL LISTED
>CIRCUIT BREAKER: ABB 1600AMP, Manual Main line circuit breaker, 3 poles, set mounted, wired and maximum output rated for complete generator protection
>DIGITAL VOLTAGE REGULATION: DEEPSEA DSEA109 Advanced Digital Voltage Regulator upgrade with optional motor soft-start ramp up capability
CORROSION-PROOF MARINE GRADE ALUMINUM ENCLOSURE FOR LIFETIME LONGEVITY AND EXCELLENT SOUND PERFORMANCE:
>ENCLOSURE CONSTRUCTION: AL5052, 12GA, Marine-Grade ALUMINUM alloy panels enclosure construction with stainless steel hardware
>ENCLOSURE TYPE: IP56 rated Weather proof, sound attenuated enclosure. 12-gauge aluminum for maximum corrosion resistance
>SOUND ATTENUATING MATERIAL: Up to 50 mm (2 in) of Polydamp® Acoustical Foam with Tuffylm® urethane lining, designed to give maximum sound absorption. The foam comes with 1.85 density (lb/ft3). Flame resistant to UL94-HF1 standard.
400 KW GENERATOR RENTAL-GRADE FEATURES FOR COMPLETE MOBILITY, TOTAL VERSATILITY AND MAXIMUM ROI:
>TRUE DOUBLE-WALLED FUEL TANK: 600Gal (2271L), double walled, integral metallic fuel tank with electronic fuel level sender for control panel readings, alarms and shutdowns. TRUE Double-walled construction with 110% containment capability and leak detection switch
>RUNTIME AUTONOMY (DIESEL): 29 Hours @ 75% load, 22 Hours @ 100% load
>ENVIRONMENTAL CONTAINMENT: 110% rated containment of oil, coolant and fuel. Segmented containment design allows for separate containment of oil-coolant, fuel and water
>VOLTAGE SELECTOR SWITCH: SALZER 3-position manual voltage selector switch for effortless switching between 1PHASE-240/120V, 3PHASE 208/120V and 3PHASE 480/277V connections
>POWER DISTRIBUTION PANEL: Enclosure-surface mounted, rental-type, full distribution panel includes: 2x 20AMP GFCI duplex receptacles, 3x 50AMP twist lock receptacles, 1x FULL SET color coded camlocks, 1x FULL SET bus bars with 500mcm mechanical lugs
>EXTERNAL SHORE POWER CONNECTOR: Externally mounted quick-connector provide convenient access to power the battery charger and coolant heater
>EXTERNAL COMMUNICATION CONNECTORS: 1x set of remote start/stop terminals and 1x surface mounted USB-B type connector for effortless control software configuration
>EXTERNAL FUEL FILL: Externally mounted lockable fuel fill installed on the enclosure
>EXTERNAL CONNECTION PORTS: 4x externally mounted quick access ports installed on the enclosure for coolant drain; oil drain; fuel supply; and fuel return
>DOUBLE CRITICAL-ACCESS EMERGENCY STOP BUTTONS: 1x externally mounted recessed emergency-stop button installed on the enclosure and 1x internally mounted button next the control cabinet
>BATTERY DISCONNECT SWITCH: Manually operated battery quick disconnect switch
>LED LIGHTING: 300 lumens, 0.3A, 12VDC, waterproof white LED strip in aluminum housing installed in the mechanical lugs compartment
>SHUNT TRIP: 12VDC shunt trip
>SYSTEM-WIDE DIFFERENTIAL PROTECTION ON ALL OUTPUTS: LOVATO 31RM48 Type A earth leakage relay with 1 operation threshold, configurable automatic or manual resetting and LED indicators
>ACCIDENTAL SWITCHOVER PROTECTION: Automatic breaker shunt-trip in the case of accidental operation of the voltage selector switch while the engine is running
BRAND NEW AND FULLY PACKAGED RENTAL GENERATOR INCLUDES STANDARD:
>AUTO start/stop control feature included for remote start via 2-Wire dry contact
>12 lead re-connectable Alternator, brushless, single bearing, IP23 drip proof, Insulation class H/H, +/- 1.0% regulation
>Microprocessor based control panel
>12V charging alternator and 12V Electric starter motor
>12V charged DC starting battery with electrolyte and cables
>Dry type Air filter, Fuel filter and Oil filter spin-on elements installed
>Mechanically welded chassis with anti-vibration isolators
>Each unit prototype and individually factory load bank tested prior to shipping in our Quality Controlled facilities in USA
>User guide, commissioning and maintenance manual. Wiring diagrams included. (English)
>Compliant with ISO3046, ISO8528, BS4999, BS5514, BS5000PT99, AS1359, IEC34, UTE5100, VDE0530
ENGINEERED FOR PRIME POWER AND PEACE OF MIND:
>QUALITY: 100% designed, engineered, assembled and individually load bank tested with pride and care in our factory in USA
>INTERNATIONAL WARRANTY: Industry-leading Comprehensive Parts AND Labor coverage for up to 1 YEAR / 2000 HOURS Prime Service Duty
>SOUND LEVELS: Super silent enclosure designed to meet and exceed North American Level 2 and European 2000/14EC Low sound level directives
GENERATOR DIMENSIONS:
>SKID MOUNTED: Please refer to exact-configuration drawings
>TRAILER MOUNTED: Please refer to exact-configuration drawings